Glow-worm Energy, Ultimate, Betacom or Flexicom showing F1, F22, F75 or F4? What each code actually means, the checks you can safely do yourself in five minutes, and the exact point where you must stop and call a Gas Safe engineer.

Quick Answer

F22 is low water pressure, and it is the one Glow-worm code a homeowner can usually clear alone by topping the system up to around 1.2 bar through the filling loop. F1 on the Betacom, Flexicom and Energy ranges is an ignition or flame fault, meaning the boiler tried to light and no flame was established, so check the gas is on at the meter, check another gas appliance such as the hob still lights, check a prepayment meter is in credit, and in cold weather check the external white condensate pipe has not frozen. F75 means the boiler started its pump and detected no corresponding change in system water pressure, which points to the water pressure sensor, the pump or a system very low on water, and diagnosis needs the casing off so it is Gas Safe work. Glow-worm has used more than one code set across its ranges, so a low-numbered code such as F1 or F4 does not mean the same thing on every model: check the number against the manual for your specific range before you act on it. Do not reset more than two or three times. Never remove the boiler casing, and if you smell gas, stop and ring the National Gas Emergency Service on 0800 111 999 first.

A Glow-worm that has stopped working and is showing a code on its display has already done you a favour. It has told you which of its internal safety checks failed. The problem is that the codes are written for engineers, so F1, F22 and F75 mean very little to a homeowner standing in a cold kitchen at seven in the morning wondering whether this is a five-minute fix or a call-out.

This guide translates the codes we attend most often on London Glow-worm installations, across the Betacom, Flexicom, Ultimate and Energy ranges. For each one you get what the boiler is actually complaining about, the checks you can safely do yourself from outside the casing, and the clear point at which you stop and ring a Gas Safe registered engineer. Nothing in here asks you to open the boiler, touch a gas component or defeat a safety device, because none of that is legal or safe for anyone who is not on the Gas Safe Register. If you want the general principle before the brand specifics, start with our guide to boiler fault codes across every brand.

⚠️ Before anything else: if you can smell gas, this is not a boiler repair problem. Turn the gas off at the meter's emergency control valve, open windows and doors, do not touch electrical switches, do not use naked flames, and ring the National Gas Emergency Service on 0800 111 999. It is free and staffed 24 hours. Repairs to the appliance happen after the supply has been made safe.

How Glow-worm Fault Codes Work

Glow-worm uses an F prefix for faults. Depending on the model and the display, the same fault appears as F.22 or F22, so treat the two as identical.

The single most useful thing to know about Glow-worm codes is where they come from. Glow-worm is part of the Vaillant Group, and the newer ranges are built on the Vaillant control platform. That is why F22 for low water pressure and F75 for no pressure change on pump start mean the same thing on a Glow-worm as they do on a Vaillant ecoTEC, and why an engineer who works on one is immediately at home with the other. Our Vaillant fault code guide covers those two codes in more depth and the detail carries across.

The corresponding warning is that this does not apply to every code or every range. Glow-worm has also sold boilers that predate that platform and use a different code set, and the low-numbered codes are exactly where the two sets diverge. The same F1 or F4 can point at an ignition fault on one range and a temperature sensor fault on another. So use the shared codes with confidence, treat the low-numbered ones as model-specific, and check anything you are unsure about against the manual for your exact model.

💡 Write down the code and the model name together. On a Glow-worm the pair matters more than on most brands, because the code alone is ambiguous across ranges. The model name is printed on the front panel and the GC number is on the data badge. Note both before you reset, because some models clear the code from the display afterwards.

The last thing to hold on to is the general principle: a fault code names the check that failed, not the part that broke. F75 does not mean "your pump is dead". It means the boiler expected to see a pressure change when the pump ran and did not see one. That could be the pump, the sensor that reads the pressure, or the water in the system. Which of the three it is takes a meter and a set of eyes inside the casing.

F22: Low Water Pressure

What the boiler is saying: there is not enough water in the sealed heating circuit to fire safely, so I have shut down before I damage the heat exchanger by running it dry.

This is the friendliest code on the page, and the only one a homeowner can usually resolve without an engineer, because everything you need to touch is outside the casing.

What you can safely check and do yourself

  • Read the pressure gauge on or near the boiler, or the digital pressure reading on the display. Below about 1 bar when the system is cold is low; below roughly 0.8 bar is usually a lockout.
  • Top the system up through the filling loop. On most Glow-worm installations this is a short braided metal hose underneath the boiler, often with two lever handles that need opening together. Some models use a built-in filling arrangement instead, so if there is no braided hose in sight, check your model's user guide rather than hunting for one. Our step-by-step repressurising guide walks the whole process and shows the valve types.
  • Stop at 1.2 bar. Do it with the boiler switched off and cool, open the valves slowly, and close them the instant the needle reaches 1.2. Releasing excess pressure is far more awkward than adding it.
  • Reset once if the code has not cleared by itself when you switch the boiler back on.

When you stop and call an engineer

Call if the pressure will not rise at all when you open the filling loop, if the code persists at 1.2 bar, or if the gauge reads above 2.5 to 3 bar, in which case the answer is to release pressure rather than add it and that is not a homeowner job.

More importantly, call if F22 keeps coming back. A sealed system that is behaving should hold pressure for six to twelve months between top-ups. If you are topping up weekly, the water is going somewhere: a weeping radiator union, a hidden pipe joint, a failed expansion vessel, or a pressure relief valve discharging out through the wall. Repeated topping up masks the fault and pumps fresh oxygenated water into the system, which accelerates corrosion in the radiators and the heat exchanger. We rank the four causes by how often we actually see them in why your boiler keeps losing pressure.

Free 30-second diagnostic: step outside and look at the brass pipe that terminates low on the external wall near the boiler. If it is wet, dripping, or streaked with white limescale, the pressure relief valve has been discharging and your F22 almost certainly traces back to a failed expansion vessel. Telling the engineer that on the phone can halve the diagnosis time on site.

⚠️ If the pressure is dropping because water is visibly coming out somewhere, isolate the water before you worry about the boiler code. Our guide to turning the water off at the mains in London covers where the stopcock hides in Victorian terraces, 1930s semis and flats, and how to isolate a single radiator or appliance instead of the whole property.

F1: Ignition or Flame Fault (Betacom, Flexicom and Energy)

What the boiler is saying: I ran my ignition sequence and no flame was established, or a flame I did establish was lost, so I have stopped rather than keep trying.

On the Glow-worm ranges most people are looking this up for, F1 is an ignition or flame fault, and you can usually hear it happening: a run of clicks from the ignition electrodes, a pause, another attempt, and then the code. Because the complaint is that the boiler could not light, every productive check is about whether gas is actually reaching the appliance and whether the combustion and condensate paths are clear. All of those checks sit outside the casing, and in a London winter there is a genuinely good chance one of them fixes it without a call-out at all.

⚠️ Check F1 against your own model's manual before acting on it. Glow-worm has used more than one code set, and on models built on the Vaillant control platform the low-numbered codes are temperature sensor faults rather than ignition faults. The checks below are safe to do regardless, because none of them involve touching the boiler. But do not conclude you have an ignition problem on the strength of a generic table.

What you can safely check and do yourself

1

Confirm the gas supply is actually on

Find the emergency control valve at the gas meter. When the lever sits in line with the pipe the gas is on; across the pipe it is off. It is more common than you would think for a valve to have been turned off during other work and never turned back.

2

Test another gas appliance

Try the gas hob. If the hob will not light either, the problem is the supply rather than the boiler, and that is a very different phone call. If the hob lights normally, gas is reaching the property and the issue is at the boiler.

3

Check the meter is in credit

On a prepayment meter, a boiler that has run out of credit and been topped back up sometimes needs the emergency credit accepted at the meter before gas flows properly again. Worth 30 seconds before you pay a call-out fee.

4

In cold weather, check the condensate pipe

Find the white plastic pipe leaving the property, usually 22mm or 32mm and often the only white pipe on that wall. After a hard frost it can freeze solid, and a blocked condensate route commonly presents as an ignition or lockout fault, frequently with a gurgling sound as the boiler tries and fails. Pour warm, never boiling water along it, concentrating on external bends and the exposed end. Boiling water can crack the pipe or its fittings.

5

Reset once, and once more at most

Hold the reset button or the flame symbol for around five seconds. If the boiler fires and stays running, you have found it. If the code returns, stop resetting and book an engineer.

When you stop and call an engineer

If the gas is on, other appliances work, the meter is in credit and the condensate pipe is clear, then the remaining causes all sit inside the appliance. The gas valve, the ignition and flame sensing electrodes, the fan and the flue are Gas Safe territory without exception. Two resets is the limit. A lockout after failed ignition is the boiler doing precisely what it is designed to do, and repeatedly forcing it to retry a start sequence it has already judged unsafe is the one thing you should not do.

If a frozen condensate pipe turns out to be the culprit and it keeps refreezing every cold snap, ask an engineer to re-route it internally or lag it properly. It is a cheap job that saves a winter of call-outs, and we cover the wider picture in our frozen pipes guide for London.

F75: No Pressure Change Detected When the Pump Starts

What the boiler is saying: I started the pump at the beginning of a demand and expected the water pressure to change as water began to move. It did not change, so I do not trust that the circuit is circulating and I have shut down.

F75 is one of the codes Glow-worm shares directly with Vaillant, and it is widely misread as "the pump has failed" by people who then find the pump is fine. The boiler is reporting a mismatch between two things: the pump running, and the water pressure sensor reporting a change. In practice, three causes cover the overwhelming majority of F75 call-outs.

  • A faulty water pressure sensor. The sensor reads system pressure and reports it to the boiler's control board. In London's hard water areas it scales up and stops reading changes accurately, so the boiler sees a flat line even though the pump is doing its job. This is the most common single cause we find.
  • A failed, seized or airlocked pump. If the pump genuinely is not moving water, the boiler is correct to shut down. Pumps seize after long summer idle periods, which is why the first cold week of October is always the busiest of the year, and sludge in an older London system is a frequent contributor.
  • Very low system water. If pressure is already near zero there is little for the pump to act on, and F75 can appear alongside or instead of F22.

What you can safely check and do yourself

  • Check the pressure gauge first. This is the only cause of the three you can address from outside the casing. If it reads below 1 bar, top up to around 1.2 bar through the filling loop exactly as described for F22 above.
  • Reset once after topping up, and give the boiler a full start cycle.
  • Listen. Stand near the boiler on a demand. A pump that hums but produces no flow sound, or a boiler that is silent where you would normally hear circulation, is a useful observation to pass on. Listening is fine. Opening anything to look is not.

⚠️ Stop here. Both the water pressure sensor and the pump sit inside the boiler casing. Under the Gas Safety (Installation and Use) Regulations 1998, opening that casing is restricted to a Gas Safe registered engineer. There is no homeowner test, no bypass, and no reset trick that resolves a genuine sensor or pump fault. If F75 returns after one top-up and one reset, book the visit.

The good news is that F75 is normally a same-visit fix. A water pressure sensor is an inexpensive part and a straightforward swap, and an engineer who knows the code before arriving will usually carry one.

F4 and the Codes That Vary by Range

This is the section where we are going to be honest rather than complete, because on Glow-worm that is the more useful thing to be.

F4 is a code we will not give a single definitive meaning for. Glow-worm has used more than one code set across its ranges, and the low-numbered F codes are exactly where those sets diverge. Depending on the range, a code in that group can relate to a temperature sensor, to flame detection, or to a safety shutdown. Publishing one answer would send a decent share of readers looking at the wrong component, and on a gas appliance that is not a harmless mistake.

What is consistent is what you should do:

1

Record the code and the model together

Note the code exactly as it appears, including the dot if there is one. Note the model name from the front panel and the GC number from the data badge. That pair is what lets anybody look it up correctly.

2

Check it against your own manual

The installation and servicing instructions published for your specific Glow-worm model are the authoritative list. Anything you read online, including this page, is a starting point rather than a substitute.

3

Do the checks that are safe whatever the code means

Read the pressure gauge. Confirm the gas is on at the meter and that another gas appliance lights. Confirm a prepayment meter is in credit. In cold weather, check the external condensate pipe has not frozen. None of these involve touching the boiler, and all of them are worth doing regardless of what the number turns out to mean.

4

Quote the code and the model when you ring

An engineer with both can cross-reference your unit before they arrive. An engineer with only the code is guessing along with you.

The same applies to any other Glow-worm code not covered above. We have deliberately kept this page to the codes we can stand behind rather than reproducing a long list of half-remembered numbers, because a confident wrong answer about a gas appliance is worse than no answer.

CodeWhat it indicatesHomeowner or engineer?
F22Low water pressure in the sealed systemHomeowner can top up to around 1.2 bar via the filling loop
F75No pressure change detected when the pump startsCheck pressure only, then engineer
F1 (Betacom, Flexicom, Energy)Ignition or flame fault, no flame established or flame lostGas, meter and condensate checks only, then engineer
F4 and other low-numbered codesMeaning varies by range. Do not act on a generic tableCheck your model's manual, do the safe external checks, then quote code and model
Any code you cannot findUnknown. Glow-worm ranges use overlapping but not identical code setsNote it exactly with the model name, and quote both on the phone

Resetting a Glow-worm Safely

On most Glow-worm models the reset is a dedicated button or the flame symbol on the control panel, held for around five seconds until the display responds. That much is straightforward. The discipline is in how often you use it.

  • Only reset after you have changed something. Topping the pressure up, thawing a condensate pipe or turning the gas back on are changes. Pressing reset again five minutes later is not.
  • Two or three attempts, maximum. Once a fault persists through a small number of resets, stop and get qualified help.
  • A code that clears and returns the same day is a persistent fault. Book the visit rather than resetting through the evening.
  • Never reset an overheat or safety shutdown repeatedly. If the boiler is banging, kettling or smells of scorching, turn it off at the switched fused spur and book the visit as an emergency.

The lockout is not the boiler being awkward. It is a safety mechanism that has decided a start sequence is not safe to repeat, and overriding it by habit is how a cheap sensor fault becomes an expensive one.

Where You Must Stop: The Gas Safe Line

This is the part that matters more than any code on this page. Under the Gas Safety (Installation and Use) Regulations 1998, work on a gas appliance in the UK may only be carried out by an engineer on the Gas Safe Register. Removing the casing of a sealed-system gas boiler counts as work on the appliance. It is a criminal offence for anyone else to do it, it invalidates the boiler warranty and often the home insurance, and it puts you alongside live mains electrics, a pressurised water circuit and a gas carrying component simultaneously. It also breaks the room-sealed integrity of the appliance, which is what keeps combustion products in the flue rather than in your home.

So the boundary is simple and it is physical: outside the casing is yours, inside the casing is not.

💡 Outside the casing, and yours to do: reading the pressure gauge or digital pressure display, using the external filling loop, checking the gas meter's emergency control valve and other gas appliances, confirming prepayment credit, thawing an external condensate pipe with warm water, checking the outside pressure relief discharge pipe for drips, checking the room thermostat and radiator valves, using the reset control, and writing the fault code and model name down.

⚠️ Inside the casing, and never yours to do: the pump, the water pressure sensor, the gas valve, the ignition and flame sensing electrodes, the fan, the overheat limiter, the expansion vessel, the pressure relief valve, the diverter valve, the heat exchanger, the PCB and the flue. There is no exception to this for "just having a look", and there is no circumstance in which bypassing or defeating a safety device is acceptable.

When an engineer does attend, ask to see their Gas Safe ID card and check the registration number at gassaferegister.co.uk. The card shows which appliance types they are qualified to work on, and the number on the card should match the one on your invoice.

What These Repairs Typically Cost in London (2026)

Indicative London pricing. The call-out covers travel and the first 45 minutes on site including diagnosis, and any parts are quoted before fitting rather than after.

JobTypical London cost (2026)Notes
Call-out + diagnosis (weekday daytime)£60Includes first 45 minutes on site
Call-out + diagnosis (out-of-hours / weekend)£90Same 45-minute window
Repressurise, reset or minor fix (no parts)£60–£120Often completed inside the call-out window
Frozen condensate re-route + lag£90–£160Stops the ignition lockout recurring every cold snap
Expansion vessel / pressure relief valve£120–£280The usual cause behind a repeating F22
Diverter valve replacement£150–£320Common combi hot-water fault
Pump replacement£180–£380Part and labour, one of the F75 outcomes
Fan replacement£200–£420Part price varies by model
PCB (circuit board) replacement£350–£650Often the repair versus replace tipping point
Primary heat exchanger£450–£750+Scale-related; may favour replacement

Two things are worth knowing before you book. First, the call-out is not dead money: on most fault code jobs the diagnosis and a minor fix both happen inside that first window, so plenty of visits finish at the £60 to £120 mark. Second, if the diagnosis lands on a PCB or a heat exchanger on a boiler that is already 12 to 15 years old, pause and price a replacement before committing. Our emergency boiler repair guide for London sets out the full repair versus replace maths.

Landlords: A Fault Code Is a Repair Clock Starting

If you let the property, a locked-out boiler is a legal matter as well as a practical one. Under Section 11 of the Landlord and Tenant Act 1985 you must keep the installations for space heating and hot water in repair and proper working order. Under the Homes (Fitness for Human Habitation) Act 2018, a home left without heating or hot water, particularly in winter or where a child, an elderly or a vulnerable tenant lives, can be judged unfit for human habitation.

There is no single statutory deadline, but the accepted benchmark is to act within roughly 24 hours for a total loss of heating or hot water, and same day where a vulnerable person is affected. Two practical points: ask the tenant to photograph the display showing the code and to note the model name from the front panel, which speeds up the dispatch and gives you a dated record, and never coach a tenant into opening the boiler. Separately, the annual Gas Safety Record (CP12) from a Gas Safe engineer is required for every gas appliance in the property regardless of whether anything has broken.

Frequently Asked Questions

What does F22 mean on a Glow-worm boiler and can I fix it myself?
F22 is low water pressure, sometimes described as dry fire protection: the boiler has detected too little water in the sealed circuit to fire safely. It is the one code here a homeowner can usually clear alone. With the boiler off and cool, open the filling loop valves slowly, watch the gauge, close them at around 1.2 bar, then switch on and reset if needed. What matters more is what happens next. A healthy sealed system holds pressure for six to twelve months. If F22 returns within days or weeks you have a leak, a failed expansion vessel or a weeping pressure relief valve, and repeated topping up only accelerates corrosion inside the system.
What does F1 mean on a Glow-worm boiler?
On the Betacom, Flexicom and Energy ranges, F1 is an ignition or flame fault: the boiler ran its ignition sequence and no flame was established, or a flame it did establish was lost. Check the gas is on at the meter's emergency control valve, check another gas appliance such as the hob still lights, check a prepayment meter is in credit, and in cold weather check the external white condensate pipe has not frozen (pour warm, never boiling, water along it). One caveat: Glow-worm has used more than one code set, and on some models built on the Vaillant control platform the low-numbered codes are temperature sensor faults instead. Check F1 against the manual for your specific range before assuming it is an ignition problem.
What does F75 mean on a Glow-worm boiler?
F75 means the boiler started its pump and detected no corresponding change in system water pressure, so it shut down rather than firing into a circuit it cannot confirm is circulating. Three causes dominate: a faulty water pressure sensor (the most common, and often scale-related in London), a failed, seized or airlocked pump, and a system very low on water. The one useful self-check is the pressure gauge. If it reads below 1 bar, top the system up to around 1.2 bar through the external filling loop and reset once. If F75 returns at correct pressure, stop. Both the sensor and the pump sit inside the casing, and that is Gas Safe engineer work by law.
Are Glow-worm and Vaillant fault codes the same?
On the newer ranges they largely are. Glow-worm is part of the Vaillant Group and the recent ranges use the Vaillant control platform, which is why F22 for low water pressure and F75 for no pressure change on pump start mean the same thing on both. It is not a licence to read across every code, though. Glow-worm has also sold ranges that predate that platform and use a different code set, so the same low-numbered code can mean an ignition fault on one range and a temperature sensor fault on another. Use the shared codes with confidence and check the rest against the manual for your exact model.
What does F4 mean on a Glow-worm boiler?
This is one we deliberately will not give a single answer for. Glow-worm has used more than one code set, and the low-numbered F codes are exactly where those sets diverge, so depending on the range a code in that group can relate to a temperature sensor, to flame detection or to a safety shutdown. Note the code exactly, note the model name from the front panel and the GC number from the data badge, and check them against the installation and servicing instructions for your specific model. Meanwhile do the checks that are safe regardless: read the pressure gauge, confirm the gas is on and another appliance lights, confirm a prepayment meter is in credit, and in cold weather check the external condensate pipe has not frozen.
How many times can I reset a Glow-worm boiler?
Two or three attempts at most, and only after you have made an actual change such as topping the pressure back up, turning the gas back on or thawing a frozen condensate pipe. A lockout is a deliberate safety response, not a glitch. On most models the reset is a dedicated button or the flame symbol held for around five seconds. If a code clears and returns the same day, treat it as persistent and book a visit. Note the code and the model name before you reset, because some models clear the code from the display afterwards.
Is a Glow-worm fault code an emergency?
It depends on the code and who is in the house. Treat it as a same-night emergency if there is no heating or hot water in cold weather with a baby, an elderly person or anyone unwell at home, if the boiler is leaking water, if there is a burning smell, if it is banging or kettling, or if it keeps locking out and will not stay running. Any smell of gas comes first and is handled differently: turn the gas off at the meter, ventilate, avoid switches and flames, and ring 0800 111 999. A single F22 on a mild day that clears after a top-up can usually wait for a weekday daytime slot at the lower call-out rate.
Can I take the cover off my Glow-worm boiler to look inside?
No. Under the Gas Safety (Installation and Use) Regulations 1998, work on a gas appliance is restricted to Gas Safe registered engineers, and removing the casing of a sealed-system gas boiler counts as work on the appliance. It is illegal, it invalidates the warranty, and it puts you next to live electrics, a pressurised water circuit and a gas carrying component at once. Everything genuinely useful to a homeowner is outside the casing: the pressure gauge, the filling loop, the gas meter, other gas appliances, the external condensate pipe, the outside pressure relief discharge pipe, the room thermostat and the reset control.

The Bottom Line

Of the codes on this page, F22 is the only reliable homeowner fix, and even then a repeating F22 is a leak or an expansion vessel telling you something. F1 on the ranges where it is an ignition fault gives you four checks worth doing (gas on, other appliances, meter credit, frozen condensate) and a decent chance of clearing it yourself in a London winter. F75 gives you one check worth doing (the pressure gauge) before the diagnosis moves inside the casing. And F4, along with the other low-numbered codes, is a reminder that on a Glow-worm the code alone is not enough: the model name is half the answer.

Note the code exactly as displayed along with your model name, do the outside-the-casing checks, reset no more than twice, and if you smell gas ring 0800 111 999 before anything else.

Emergency Repairs London provides same-day and 24/7 emergency boiler repair with Gas Safe registered engineers across all 32 London boroughs, including Glow-worm diagnostics and sensor, pump, fan and expansion vessel replacement. Fixed £60 daytime call-out, quoted before work starts. Lines are open 24/7 on 0207 046 1363.

Key Takeaways

  • Glow-worm uses an F prefix for faults, shown as F.22 or F22 depending on the display. Treat the two as identical.
  • Glow-worm is part of the Vaillant Group, and the newer ranges share the Vaillant control platform. That is why codes such as F22 and F75 mean the same thing on a Glow-worm as on a Vaillant ecoTEC.
  • F22 is low water pressure. Top the system up to around 1.2 bar through the filling loop and reset. This is the one code most homeowners fix without an engineer.
  • F1 on the Betacom, Flexicom and Energy ranges is an ignition or flame fault. Check gas on, other appliances, meter credit and the external condensate pipe before you ring.
  • F75 means the pump ran but the boiler saw no corresponding pressure change. Usual suspects are the water pressure sensor, the pump, or a system with too little water in it. Diagnosis needs the casing off.
  • Low-numbered codes such as F1 and F4 do not mean the same thing across every Glow-worm range. Check the number against the manual for your specific model rather than a generic table.
  • Do not press reset more than two or three times, and only after you have actually changed something. Repeated resets on an unresolved gas fault are exactly what the lockout exists to prevent.
  • Never remove the boiler casing. Under the Gas Safety (Installation and Use) Regulations 1998 that work is restricted to a Gas Safe registered engineer, and it is a criminal offence otherwise.
  • Any smell of gas is not a boiler repair call. Turn the gas off at the meter, ventilate, and ring the National Gas Emergency Service on 0800 111 999.
  • A London Gas Safe call-out is £60 weekday daytime and £90 out-of-hours, covering travel and the first 45 minutes including diagnosis.
James Harrington

Written by James Harrington

Gas Safe Registered Engineer
Gas Safe Registered  ·  London Emergency Plumbers

James has been a Gas Safe registered plumber in London since 2011, specialising in emergency repairs, boiler installations, and central heating systems across all 32 London boroughs. Glow-worm Betacom, Flexicom and Energy units are common across London's rental stock and 2000s conversions, and pressure and ignition faults are the two Glow-worm call-outs he runs most often between October and April.

Chat on WhatsApp