
Range Tribune Installation London
G3 qualified install of Range Tribune HE unvented cylinders across every London borough. From £1,495 fitted for 120L. UK-manufactured duplex stainless steel, 25-year tank warranty, Benchmark logbook and Building Regulations Part G3 notification included on every job.
Indirect, Direct, Slimline, Horizontal, Solar twin-coil and Heat Pump variants. Same-day surveys, fixed-price quotes before any work begins.
The Range Tribune HE is a UK-manufactured duplex stainless steel unvented hot water cylinder, made in Birmingham, with a 25-year tank warranty and Benchmark commissioning. London fitted prices run from £1,495 (120L Indirect) to £2,595 (300L Indirect). Installation is a controlled service under Approved Document G3 — every install carries Building Regulations notification, full safety group and witnessed T&P testing. Call 0207 046 1363 for a same-day survey.
What is the Range Tribune HE?
Range Cylinders is a Birmingham-based manufacturer that has been building hot water cylinders for British homes for over seven decades. The Tribune HE is their flagship high-efficiency unvented range — duplex stainless steel (typically 2304 or 2205 grade), TIG-welded, pressure-tested and factory-foamed with high-density polyurethane to minimise standing heat loss. Every cylinder ships with a 25-year tank warranty when installed by a G3-certified engineer and serviced annually.
The Tribune HE family covers every common UK install scenario. Standard Indirect is the workhorse — paired with a gas system or heat-only boiler via a single coil, this is the version that lands in most London 2–4 bed homes. Direct variants ditch the coil for twin immersion heaters, suited to all-electric flats and Economy 7 tariffs. Solar twin-coil pairs a renewable input with a boiler back-up. Heat Pump variants oversize the coil for low-grade flow temperatures. Slimline drops the diameter to 475 mm for tight London cupboards, and Horizontal lets you mount the cylinder on its side in lofts or low-ceiling spaces.
The case for the Tribune HE in London is straightforward — it matches Megaflo and Gledhill on warranty and compliance, sits 10–15% below them on RRP, and the manufacturer is two hours up the M40 if a warranty claim ever needs handling. For hot water cylinder replacement where the budget matters as much as the spec, the Tribune HE is the value pick that gives nothing up on the long-term warranty.
Range Tribune HE — the full range
Six variants cover almost every London install scenario. Survey first — the variant choice is set by the boiler type, the cupboard dimensions, and any renewables already on the property.
| Variant | Use case | Sizes available |
|---|---|---|
| Tribune HE Indirect | Most common — paired with a gas system boiler. Single coil for primary heating. | 90, 120, 150, 180, 210, 250, 300L |
| Tribune HE Direct | All-electric homes / flats with no gas. Twin immersion heaters, no boiler coil. | 120, 150, 180, 210, 250L |
| Tribune HE Solar | Twin-coil for solar thermal pairing. Lower coil takes solar gain, upper coil takes boiler back-up. | 180, 210, 250, 300L |
| Tribune HE Heat Pump | Larger lower coil sized for low-grade heat pump flow temperatures (45–50°C). | 180, 210, 250, 300L |
| Tribune HE Slimline | Reduced diameter (475 mm) for tight London airing cupboards in mansion blocks. | 120, 150, 180L |
| Tribune HE Horizontal | Horizontal mount for low-ceiling cupboards and loft installs. Same duplex stainless construction. | 150, 180, 210L |
Sizing — what litreage do I need?
Range follow the Hot Water Association rule of thumb: 35–45 litres of storage per occupant, plus 50 litres for any property with a daily-used bath. Over-sizing wastes standing heat. Under-sizing means cold-shower complaints in the second bathroom. The recommendations below cover most London property types.

| Property profile | Recommended Tribune HE |
|---|---|
| 1-bed flat, 1 occupant, 1 shower | 120L Tribune HE Direct or Indirect |
| 2-bed flat, 2 occupants, 1 bathroom | 150L Tribune HE Indirect |
| 3-bed terrace, 3–4 occupants, 1–2 bathrooms | 180L Tribune HE Indirect |
| 3–4 bed, 2 bathrooms (one en-suite) | 210L Tribune HE Indirect |
| 4–5 bed family home, 2 bathrooms, daily bath | 250L Tribune HE Indirect |
| 5+ bed / 3-bathroom / freestanding bath | 300L Tribune HE Indirect |
| Property with solar thermal panels | 210–300L Tribune HE Solar (twin-coil) |
| Air-source heat pump install | 250–300L Tribune HE Heat Pump (oversized coil) |
Tribune HE vs Megaflo vs Gledhill — brand comparison
Five brands dominate London unvented installs. All are duplex stainless, all carry a 25-year tank warranty conditional on annual G3 servicing. The decision usually comes down to price, parts depth and physical footprint.
| Brand | Origin | Warranty | Notes |
|---|---|---|---|
| Range Tribune HE | Manufactured in Birmingham, UK | 25-year tank / 2-year parts | Duplex stainless 2304/2205. Strong UK service network. Tribune HE 180L is the workhorse London swap. |
| Megaflo Eco (Heatrae Sadia) | UK / Italy assembly | 25-year tank / 2-year parts | Strongest London parts supply (PRVs, vessels, elements stocked on most vans). Higher RRP than Tribune. |
| Gledhill StainlessLite Plus | Blackpool, UK | 25-year tank / 2-year parts | Slightly faster recovery. Bigger physical footprint — sometimes too wide for narrow London cupboards. |
| OSO Super S | Hokksund, Norway | 25-year tank | Premium high-flow Scandinavian cylinder. Excellent for multi-bath homes. Highest price point. |
| Kingspan Albion Ultrasteel | Telford, UK | 25-year tank / 2-year parts | Strong on-flow performance. Good London availability. Comparable to Tribune HE on price. |
Range Tribune installation cost London — 2026 prices
Every quote is fixed in writing on site after a 30-minute survey. No call-out fee on quoted work, no parking add-ons, no surprise extras for discharge routing. Prices include VAT, cylinder supply, full G3 safety group, all copper pipework, commissioning, Benchmark logbook, Building Regulations notification, removal & disposal of the old unit, and a 12-month workmanship guarantee.
| Job | What's included | Typical cost |
|---|---|---|
| Range Tribune HE 120L (indirect) — supply & fit | 120L Tribune HE indirect cylinder, full G3 inlet group, expansion vessel, discharge pipework to outside, commissioning, Benchmark logbook, Building Regs G3 notification. | From £1,495 |
| Range Tribune HE 150L (indirect) | 150L Tribune HE indirect, G3 inlet kit, vessel, tundish + discharge, primary connections, commissioning, certificate. | From £1,595 |
| Range Tribune HE 180L (indirect) | 180L Tribune HE — most common London 3-bed swap. Full safety group, discharge route, removal & disposal of old unit. | From £1,745 |
| Range Tribune HE 210L (indirect) | 210L Tribune HE for 3–4 bed with two bathrooms. Full G3 fit, balanced cold feed if specified, commissioning. | From £1,895 |
| Range Tribune HE 250L (indirect) | 250L Tribune HE for larger families and high-flow showers. G3 fit, Benchmark, building control notification. | From £2,195 |
| Range Tribune HE 300L (indirect) | 300L Tribune HE for 5+ bed / 3-bath / freestanding bath properties. Includes mains pressure & flow survey. | From £2,595 |
| Range Tribune HE Solar twin-coil 250L | Twin-coil cylinder for solar thermal or heat-pump pairing. Bottom coil for renewable input, top coil for boiler back-up. | From £2,495 |
| Range Tribune HE Direct (electric only) | All-electric direct Tribune — twin immersion configuration, no boiler coil. Suited to all-electric flats. | From £1,395 |
| Annual G3 service — Tribune HE | 12-point service: expansion vessel pre-charge, T&P witnessed lift, PRV outlet pressure, immersion resistance, anode check, Benchmark refresh. | £155 |
| Vented to Tribune HE conversion | Old vented cylinder + loft tank removal, new mains feed, G3 group, discharge route, Tribune HE indirect supply & fit, certificate. | From £2,495 |
* Direct (all-electric) variants typically £100 below the equivalent Indirect. Vented→Unvented conversions add £500–£800 on top depending on size. Solar / heat-pump variants £150–£250 premium.
Need a Tribune HE quote on your cupboard?
Call 0207 046 1363Installation process — survey to certificate
Survey & fixed quote
30 min — usually freeEngineer measures cupboard, checks cold mains static pressure and dynamic flow at the kitchen tap, confirms a viable discharge route to outside, sizes the cylinder against bathrooms and occupants. Written fixed quote on the day. Call 0207 046 1363 to book.
Strip-out & old unit removal
1–2 hoursIsolate cold mains, drain the old cylinder and any loft tank, cap redundant pipework, remove the old unit and any header/cold-feed tanks. Old cylinder taken away for licensed scrap recycling — no skip charge.
Tribune HE positioning & primary connections
1.5–2 hoursPosition the new Tribune HE on a manufacturer-spec base, level, connect primary flow & return in 22 mm copper for indirect models, electrical isolation for any immersion, expansion vessel on the cold leg, full G3 inlet group with WRAS-approved fittings.
Discharge pipework — D1 & D2
1 hourD1 from the T&P valve to the tundish in copper to BS EN 1057, 300 mm air gap visible. D2 from tundish to outside termination — one pipe size larger than D1 (22 mm typical), continuous fall, maximum three bends, terminating to a safe visible location above an external gully.
Commissioning & Benchmark handover
45–60 minPressurise the system, set PRV outlet to 3.0–3.5 bar, pre-charge the expansion vessel, witness-test the T&P valve, verify the energy cut-out, run up to 60°C, complete the Benchmark logbook, file the Building Regulations G3 notification through our Competent Persons Scheme. Compliance certificate posted within 30 days.
G3 compliance & Benchmark commissioning
Approved Document G3 of the Building Regulations is the statutory framework for unvented hot water in England and Wales. Every Tribune HE install must be carried out by a G3-certified engineer (BPEC HWSS, LCL Awards or City & Guilds 6035), notified to building control either directly or through a Competent Persons Scheme, and commissioned to the manufacturer's schedule on the Benchmark logbook.

Approved Document G3 — Hot water supply and systems
Sets the four-layer safety requirement (thermostat, energy cut-out, expansion device, T&P relief valve), the qualification requirement for installers, and the building control notification rules. Non-G3 installs are non-compliant and void manufacturer warranty.
Specification for indirectly heated unvented storage water heaters
The European product standard the Tribune HE is manufactured to. Governs cylinder construction, safety device layout, labelling and pressure testing.
HHIC Benchmark commissioning scheme
The industry-standard logbook completed and signed at the end of every install. Records inlet pressure, vessel pre-charge, T&P test result, stored temperature and electrical safety. Range require a completed Benchmark to honour the 25-year tank warranty.
Water Regulations Approval Scheme
Every wetted component on a Tribune HE install — fittings, valves, expansion vessel, discharge tundish — is WRAS-approved under the Water Supply (Water Fittings) Regulations 1999.
Competent Persons Scheme (WaterSafe / BESCA)
We self-certify Tribune HE installs through our Competent Persons Scheme registration. The Building Regulations G3 Compliance Certificate is posted directly to the customer within 30 days — no separate building control fee.
Real Tribune HE jobs — worked examples
Five anonymised Tribune HE jobs from the last twelve months across London, with the brief, the work done and the final fitted figure.
Battersea, SW11 — Tribune HE 180L T&P discharging on heat-up
Customer reported steady drip from the tundish 18 months after a Tribune HE install elsewhere. On-site diagnostic: expansion vessel pre-charge collapsed to 1.4 bar (factory spec 3.0 bar). External 18L vessel fitted on the cold leg, recharged to manufacturer pressure, system bled, T&P witnessed-tested clean. 95 minutes on site. £265 inc. VAT. Tribune warranty kept intact because the original install was on a Benchmark logbook.
Clapham, SW4 — like-for-like Tribune HE 210L swap
1990s vented cylinder + loft tank serving a 4-bed Victorian terrace with two bathrooms. New mains supply already in 22 mm copper, so a straight conversion to a Tribune HE 210L Indirect. Removed loft tank, capped redundant feeds, fitted Tribune HE with full G3 group, discharge through external wall to gully. Day-and-a-half install. Final invoice £2,140 inc. VAT, 25-year tank warranty registered with Range that afternoon.
Camden, NW1 — Tribune HE Slimline 150L in narrow cupboard
Mansion block airing cupboard 510 mm wide — too narrow for a standard Megaflo. Specced a Tribune HE Slimline 150L (475 mm diameter) for a 2-bed flat with one bathroom and a separate shower. Install completed in a single day, discharge piped through an existing external wall vent. £1,795 inc. VAT.
Wandsworth, SW18 — Tribune HE Solar twin-coil pairing
Roof solar thermal install on a 4-bed home, no existing cylinder big enough to accept the panel output. Replaced an old 150L Megaflo with a 250L Tribune HE Solar twin-coil. Bottom coil to the panels, top coil to the system boiler. Set legionella cycle on the boiler to maintain 60°C overnight when solar gain is low. £2,895 inc. VAT, two-day install.
Islington, N1 — emergency Tribune HE replacement after tank rupture
Existing 15-year-old non-Tribune indirect cylinder split internally — water staining and dripping from the foam jacket. Same-day attendance, isolated the leak, drained down, source of leak confirmed as tank wall failure (warranty already expired). Quoted and fitted a Tribune HE 180L Indirect within 28 hours of the first call. £1,795 inc. VAT, hot water restored same week.
Tribune HE quote this week?
Same-day surveys, fixed-price quote before any work begins, full G3 install with Benchmark logbook and Building Regulations notification. 12-month workmanship guarantee on top of the 25-year Range tank warranty.
Areas covered across London
Range Tribune HE installs carried out across every London borough. Heaviest call volumes for cylinder swaps from Wandsworth, Clapham, Camden, Islington and Hammersmith & Fulham.
Frequently asked questions — Range Tribune HE
Why choose a Range Tribune over a Megaflo?
Is the Range Tribune HE made in the UK?
How long does a Tribune HE installation take in London?
Do I need a G3 engineer to install a Tribune HE?
What is the difference between Tribune HE Direct and Indirect?
Can I fit a Tribune HE Slimline in a narrow London airing cupboard?
What does the Range Tribune 25-year warranty actually cover?
What discharge pipework rules apply to a Tribune HE?
How much does a Tribune HE install cost in London?
Does a Tribune HE need annual servicing?
Can a Tribune HE work with an air-source heat pump?
What if my cold mains pressure is too low for a Tribune HE?
Will my old vented pipework work with a Tribune HE conversion?
Are you on the Range Cylinders approved installer list?
What happens on installation day?
Question not answered? Call 0207 046 1363 and talk to a G3 engineer directly — no call centre, no triage.
Service area
Tribune HE installs across London
G3 qualified Range Tribune engineers based in central London with same-day cover across all 32 London boroughs and the City. Average response time inside Zone 2 is 2 hours for emergencies; surveys booked within 3 working days.
Range Tribune HE install — fixed price from £1,495 fitted.
G3 qualified engineers across London. UK-manufactured duplex stainless, 25-year tank warranty, Benchmark logbook on every job, Building Regulations notification included. £5M public liability, fully insured.
London 247 Home Services Ltd · Company No. 17120057 · £5M public liability · G3 BPEC HWSS qualified · 24/7 emergency line 0207 046 1363